The Simco FMX-002 is a portable, non-contact digital electrostatic fieldmeter designed to locate and measure surface charges with high precision . This compact instrument is widely used in industrial and laboratory settings for assessing electrostatic field strength and distribution. Technical Specifications The FMX-002 provides accurate readings within a compact, ergonomic frame. Measurement Range: (low range) and up to (high range). Accuracy: of the reading. Measuring Distance: (approx. 1 inch). Ion Balance Range: (requires optional balance plate). Response Time: Less than 1 second. Power Source: 9V manganese battery (6F22). Weight: ) including battery. Operating Instructions To ensure accurate data, the device must be properly grounded and positioned during use. 1. Powering On and Zeroing Turn On: Press the POWER button once while the sensor is facing away from any charged objects. A single beep confirms the unit is operational. Grounding: Use the grounding lead provided to connect the conductive resin case to a known ground. Zero Adjustment: If the initial display is not , point the sensor at an uncharged area and press the ZERO button until the display resets to zero. 2. Taking a Measurement Distance Guidance: The FMX-002 uses two integrated LED guide lights to ensure the correct measuring distance. Alignment: Move the meter toward the target surface until the two light beams form concentric circles . This confirms you are exactly 25mm away from the object. Hold Function: Press the HOLD button to freeze a measurement on the LCD display, which is helpful when the screen is difficult to see during the test. 3. Ion Balance Mode To measure the efficiency of ionizers, attach the ion balance plate. Activation: Press ZERO and POWER simultaneously. The unit will beep twice, and "Hi" will flash on the screen to indicate ion balance mode. Maintenance and Cautions Calibration: It is recommended to have the unit re-calibrated annually to maintain its Storage: Store the meter in a dry, clean environment. The internal sensors are highly sensitive to mechanical shock and vibration. Sensor Care: Never touch the sensor electrodes with foreign objects, as this can lead to permanent damage or measurement failure (often indicated by an "ERR" message). Auto-Off: The device will automatically shut down after approximately 5 minutes of inactivity to preserve battery life. For complete official documentation, refer to the FMX-002 PDF datasheet or contact Simco-Ion support for current model updates.

SIMCO FMX-002 Electrostatic Fieldmeter: Complete Operation & User Manual The SIMCO FMX-002 is a legacy, highly reliable pocket-sized electrostatic fieldmeter used to locate and measure static charges. This comprehensive guide serves as a full operational manual, outlining technical specifications, setup procedures, measurement instructions, and troubleshooting steps. 1. Product Overview and Key Features The FMX-002 utilizes a vibrating chopper sensor to measure static voltages without physical contact. This design ensures accurate readings even in ionized environments. Compact Design: Lightweight, pocket-sized plastic housing. Dual Range Capacity: Automatic switching between low and high voltage ranges. Distance Guidance: Integrated LEDs ensure precise alignment. Hold Function: Freezes the display for easy reading in tight spaces. Analog Output: Allows data logging and chart recording connection. 2. Technical Specifications Specification Measuring Range Low: 0 to ±1.49 kV / High: ±1.0 kV to ±20.0 kV Measuring Distance Response Time Less than 1 second Accuracy Power Source 9V Manganese battery (6F22) Dimensions Weight ) including battery 3. LCD Screen and Display Layout The multifunction LCD screen provides real-time digital and bar-graph visual data. Bar Graph: Displays positive (red) or negative (blue) charge polarities. Numerical Readout: Shows the exact voltage value in kilovolts (kV). [HOLD]: Lights up when the hold feature is active. [IB]: Indicates Ion Balance mode (used with optional accessories). [BAT]: Flashes when the battery requires replacement. 4. Step-by-Step Operating Instructions Battery Installation Slide open the battery compartment cover on the back of the device. Connect a fresh 9V battery to the snap terminals. Place the battery into the compartment and slide the cover closed. Grounding the Meter To ensure measurement accuracy, the meter must be grounded to dissipate any static charge residing on its own housing. Insert the included ground lead into the ground snap jack on the side of the meter. Connect the opposite end (alligator clip) to a verified earth ground. Powering On and Zero Adjustment Turn on the device by pressing the POWER button once. The unit will beep. Point the sensor area away from any charged objects (point it toward an empty room or grounded surface). Press the ZERO button. The display will flash, adjust to , and emit a short double beep. Taking Static Measurements Aim the sensor front at the target surface. Move the meter closer to the target until the two focusing LED lights merge into a single concentric circle. This confirms a precise ) measurement distance. Read the voltage on the LCD display. Low Range: Displays High Range: Displays ±1.0plus or minus 1.0 . (The unit shifts ranges automatically). Using the Hold Feature While aiming at the target, press the HOLD button. The meter will beep, freeze the current value on the screen, and display [HOLD] . Retract the meter to read the display comfortably. Press HOLD again to release the screen and resume real-time measurement. 5. Maintenance and Calibration Cleaning the Sensor The sensor opening must remain clean, free of moisture, and dust-free. Blow compressed air gently into the aperture if dust accumulates. Avoid touching the internal vibrating sensor element with any physical objects. Recalibration Schedule Factory specifications recommend professional calibration once per calendar year to maintain 6. Troubleshooting Guide Probable Cause Corrective Action No display output Dead or missing battery. Install a new 9V battery. Unstable / drifting readings Device is not grounded. Securely connect the ground lead to earth ground. Constant erratic measurements Contaminated sensor head. Clear the sensor aperture gently with dry, compressed air. [BAT] icon flashes Voltage is dropping. Replace the battery immediately. Error tone on startup Sensor element fault. Contact service center for repair. If you need help with specific components of this tool, please let me know: Do you need assistance with interpreting ion balance measurements ? g., ground cords)? Propose your next step to narrow down your technical requirements .

Report: Simco FMX002 — Full Manual Summary and Key Sections Product overview

Model: FMX002 Type: Ionizing blower/ionizer (industrial static control device) Primary use: Neutralize electrostatic charge on surfaces and personnel in manufacturing/ESD-sensitive environments.

Safety warnings (critical)

Read before use. Do not operate if damaged. Keep away from flammable/explosive atmospheres. Disconnect power before servicing. Follow local electrical codes for grounding and installation. Only qualified personnel should perform maintenance involving high voltage.

Specifications (typical)

Power input: [assume typical: 100–240 VAC or 24 VDC — confirm in original manual] Frequency: 50/60 Hz (if AC) Ion balance: ±X V at 300 mm (specify from manual) Decay time: Y s (1000–100 V) at Z mm Operating temperature: 0–40°C (typical) Mounting: Bench, wall, or overhead (model-dependent) Dimensions & weight: See original manual for exact figures

Note: Exact numeric values must be taken from the official manual — the above are placeholders. Installation

Inspect unit and accessories. Mount securely using recommended brackets and orientation. Connect power per wiring diagram; ensure correct voltage and grounding. Position unit at recommended distance (typically 200–500 mm) from target. Perform initial ion balance and decay time verification.

Operation

Power on; allow warm-up (typical few minutes). Check indicator LEDs (power, fault, or ion status). Adjust fan/airflow or output settings if available to suit application. Verify effectiveness with an electrostatic field meter or voltmeter.