Zk5kx Manual Access
The physical design of the ZK-5KX makes it ideal for panel-mounting into a custom benchtop laboratory power supply housing. Front Interface Elements ZK-5KX купить на OZON по низкой цене
Short-press to enter the voltage configuration mode. One digit of the target parameter will flash. Turn the Rotary Encoder left or right to change values. zk5kx manual
: Shuts down the module if the output voltage exceeds the specified limit (Configurable range: 0.6V to 37V). The physical design of the ZK-5KX makes it
| Problem | Likely Cause | Solution | |---------|--------------|----------| | Unit does not power on | Blown fuse or reversed DC polarity | Check fuse F1 (2A slow-blow); correct wiring | | Output does not switch | Input signal missing or incorrect P01 mode | Verify input voltage; reset timer mode | | Random resets | Electrical noise from nearby VFD | Add ferrite core on power lines; separate cables | | Display shows "Err 5" | EEPROM corruption | Perform factory reset (hold Reset 10s) | Turn the Rotary Encoder left or right to change values
Cycles the top row between Output Voltage ( OUT V ), Input Voltage ( IN V ), and Module Temperature.
: Do not connect the VIN- and VOUT- lines together. Short-circuiting or bridging the input and output ground paths bypasses the onboard low-resistance current shunt resistor, causing the constant current (CC) limiting feature to fail.
Press the button once more to save your changes and exit, or let the unit idle for 10 seconds to automatically commit the settings. 3. Power Output Toggle