Typically ranges from 9 kW to 36 kW depending on the specific model variant Wittmann Tempro Plus D 360 Manual

| Symptom | Possible Cause | Suggested Action | | :--- | :--- | :--- | | | Scale buildup in heat exchanger; undersized heater element. | Perform a descaling procedure (see maintenance section of manual). Check heater contactors. | | Pressure Fluctuations | Low water level; air in the system; faulty pressure sensor. | Check and refill water level. Run an air purging cycle. Monitor pressure gauge for anomalies. | | Unit Not Reaching Setpoint | Incorrect pump speed setting; external load exceeding capacity. | Adjust pump speed (EcoDrive models) to increase flow. Verify mold requirements against unit specs. | | Touchscreen Unresponsive | Software lockup; hardware fault. | Power cycle the unit. If persistent, consult the troubleshooting guide for control board diagnostics. | | Leakage | Worn pump seals (if not mag-coupled); loose connections. | Inspect all fittings immediately. For seal replacement, refer to the unit's exploded parts diagram. | This public link is valid for 7 days

Utilize the cool down stop or cool safety temp functions within the Fn key menu. This allows the unit to cool down safely, which is crucial for protecting the heater and preventing overtemperature conditions. Can’t copy the link right now